Technical specifications
Main specifications of the FIZEPR-SW100.30.2 moisture meter for grain, feed stuff, flour, seeds and other agricultural products are listed below. If necessary, Design Bureau Fizelektronpribor, Ltd. can adapt the design of moisture meters for agricultural products to the needs of a specific enterprise.
Item No.
|
Parameter
|
Value
|
1
|
Moisture measurement range (ratio of water mass in agricultural products to the mass of products)
|
0…100%
|
2
|
Absolute moisture measurement error:
- within 0…6% moisture range
- within 6…8% moisture range
- within 8…10% moisture range
- within 10…20% moisture range
- within 20…50% moisture range
- within 50…100% moisture range
|
0.3%
0.4%
0.5%
1%
2.5%
5%
|
3
|
Permittivity measurement range
|
1…100
|
4
|
Working temperature range of sensor operation
|
-20…145°С
|
5
|
Measurement range of sensor calibration
|
5…80°С
|
6
|
Working temperature range of electronic unit operation
|
-20…80°С
|
7
|
Measurement period
|
1 sec
|
8
|
Output interface
|
RS485 Modbus RTU
4 – 20 mA
|
9
|
Electronic unit supply voltage:
|
24 V
18...36 V
|
10
|
Current consumption, maximum
|
200 mA
|
11
|
Dust and moisture ingress protection rating of electronic unit
|
IP54 group
according to GOST 14254-96
|
12
|
Dust and moisture ingress protection rating of sensor
|
IP65 group
according to GOST 14254-96
|
13
|
Length of communication cable between sensor and electronic unit
|
2…4 m (to be specified when ordering)
|
14
|
Maximum allowable length of cable for RS485 digital signal transmission from electronic unit to external control device (controller, computer), minimum
|
1000 m
|
15
|
Maximum allowable length of cable for 4-20 mA analog signal transmission from electronic unit to external indicating device (regulator meter), minimum
|
100 m
|
Scope of supply
The FIZEPR-SW100.30.2 moisture meter is supplied in the following configuration:
Item No.
|
Item description
|
Qty
|
1
|
Electronic unit VIGT.415210.101
|
1 pc
|
2
|
Sensor VIGT.415210.102 (assembly)
|
1 pc
|
3
|
Panel VIGT.415210.128 (with VIGT.415210.121 and VIGT.415210.122 coupling holders)
|
|
4
|
Technical description and operation manual VIGT.415210.100RE.
|
1 pc
|
5
|
Data sheet VIGT.415210.100PS
|
1 pc
|
6
|
Software disk
|
1 pc
|