Moisture meter FIZEPR-SW100.17.12 for concrete-mixing machines
Moisture meter FIZEPR-SW100.17.8 for concrete-mixing machines

Moisture meter for concrete mixer
FIZEPR-SW100.17.X

Get a quote

Specifications

The moisture meter is made according to VIGT.415210.100TU specifications on the base of a set of design documents VIGT.415210.100.

 

Parameter Value
Moisture measurement range - mass water content, W, % (see note 1) 0 to 100
Acceptable absolute error limits Δ, mass water content, % (Δ is calculated according to the formulae depending on W, where W – is the result of moisture measurement in percent– see note 2) Δ= 0,035+0,05·W
Temperature measurement range, °С -40… 150
Temperature range of moisture meter calibration, °С (see note 3) +5…40
Range of sensor operational temperatures, °С -20…80
Range of electronic unit operational temperatures, °С -20…80
Measurement period, sec 0,2
Output interface:
  • digital
  • current, mА


RS485 Modbus RTU

4-20
Electronic unit supply voltage, V
  • nominal
  • allowable
 

24

18...36
Current consumption, mA, not more than 200
Sensor overall dimensions, mm Ø 108х120
Sensor weight, kg 3,5
Electronic unit dimensions, mm 255 x 170 x 60
Electronic unit weight, kg 2
Enclosure protection rating of electronic unit according to IEC 60529 IP54
Enclosure protection rating of sensor according to IEC 60529 IP67
Length of communications cable between sensor and electronic unit, m (see note 4) 1,5…2
Maximum allowable length of cable transmitting RS485 digital signal from the electronic unit to an external control device (controller, computer), not less than, m 1000
Maximum allowable length of cable transmitting 4-20mА analog signal from the electronic unit to an external indicating device, not less than, m 100
Operating mode continuous

 Notes

  1. For dry and high-flow concrete-mixing machines, water content does not exceed 14%; therefore maximum moisture value of 20% (ratio of water weight to the total weight of the concrete mix) is set in the calibration characteristics for moisture meters installed in concrete-mixing machines.
  2. Calculating by the following mathematical equations (formulae) gives the following values ​​of the absolute error Δ:
    Moisture range W Acceptable absolute error limits Δ
    up to 10%

    10…20%

    20…50%

    50…100%
    0,5%

    1%

    2,5%

    5%
  3. Using the supplied software by the method described in the operating manual, the user can adjust moisture meter calibration data for the enhancement of moisture measurement temperature range.
  4. The required cable length between the sensor and the electronic unit is agreed when ordering.
Desined and supported by Formatix Labs